MAC318M – 16+2 MULTI-READER INTERFACE

Maximum 16 reader can be connected to this MAC318 (8 reader per RS485 bus). Maximum 254 unit MAC318 interface can be linked together.

Download:
Brochure
Installation Manual

Price: Contact a local reseller.
SKU: 10.05.001.00 Categories: ,

Description

MAC318 connects to host PC through RS485 or TCP/IP.

  • Provide a more efficient and centralized control for multiple readers
  • Allows grouping of multiple reader into door groups for easier management
  • Supports emergency all door open function (through software or push button)
  • Alarm output when reader is offline
  • Scheduled door unlock
  • Scheduled auto reset of anti-passback status
  • Can use connected reader to manually control other electrical equipments.
  • 4 output for scheduled automation function. IO can be programmed to turn on lights or other equipment based on weekly time schedule.

Specification

Table SP1 – 5 + 1 ZONES SPECTRA SP5500
Specification Description
Card users 15,000
Memory transaction 11,000
Time zone 63
Holiday 120
Door group

255

Anti-passback Global anti-passback among 16 readers
Node address setting On board DIP switch
Automation function Programmable 4 input and 4 output
Duress function 4 set of duress pin number
DirectPC software support YES
Programming method Program new user and operation parameters through software.
Max reader supported 16 readers
External Wiegand port for anti-passback function 2 port for in and out
User expiry date End only – Full range for all users

Parameter

Table SP1 – 5 + 1 ZONES SPECTRA SP5500
Specification Description
Environment temperature -20 C to +75 C
Serial port RS485, 9600, N, 8, 1
1 bus for host PC, 2 bus for reader.
Power consumption 15-24 VDC. Less than 2.5W.
Dimension (mm) 180(L) x 231(W) x 62 (H)
Weight

1890 g